Bracketing in Stability Studies for the US Market


For the US market, bracketing in stability studies is an acceptable reduced study design under ICH Q1D and FDA guidance. In this approach, only the extremes of selected product variables, such as the lowest and highest strengths, smallest and largest container sizes, or lowest and highest fill volumes are placed on stability and tested at every scheduled time point. The stability of the intermediate configurations is inferred from the results generated for these extremes.

For example, if a tablet is available in 5 mg, 10 mg, 20 mg and 40 mg strengths, stability testing may be conducted on the 5 mg and 40 mg strengths, while the 10 mg and 20 mg strengths are bracketed. This approach is scientifically justified when all strengths have the same or quantitatively proportional composition, are manufactured using the same process and equipment, have comparable coating systems, and use the same or equivalent container-closure system. If one strength has a different formulation, manufacturing process, coating level, tablet weight relationship or packaging configuration, it may not be adequately represented by the bracketed extremes.

Bracketing can also be applied to packaging configurations. For example, the smallest and largest HDPE bottle sizes or fill counts may be tested while intermediate configurations are omitted. However, the smallest and largest packs must genuinely represent the stability extremes. Factors such as headspace, moisture-permeation characteristics, surface-area-to-volume ratio, closure size, desiccant quantity and the number of tablets must be evaluated. The physically smallest or largest container is not automatically the worst case.

For an ANDA submission, the bracketing design should be predefined in the stability protocol and scientifically justified in Module 3.2.P.8. The submission should clearly identify the bracketed strengths or pack configurations, demonstrate formulation proportionality and manufacturing comparability, and explain why the selected extremes adequately represent the intermediate variants. Normally, the required number of primary stability batches should still be provided for the tested extremes; bracketing reduces the number of strengths or packaging configurations tested, not necessarily the number of batches or required time points.

If either extreme shows a stability failure, significant change, OOT trend or materially different degradation behaviour, the assumption supporting the design may no longer remain valid. FDA may then request stability data for the intermediate strengths or packaging configurations. Therefore, bracketing should be used only where a strong scientific relationship exists and not simply to reduce analytical workload or stability costs.

FDA recognises bracketing through ICH Q1D: Bracketing and Matrixing Designs for Stability Testing.